Author: Kim, C.
Paper Title Page
MOPA03
Beam Diagnostics for PAL-XFEL  
 
  • C. Kim, H. J. Choi, J.Y. Choi, J.Y. Huang, H.-S. Kang, D.T. Kim, I.S. Ko, E.H. Lee, B.R. Park, J.C. Yoon
    PAL, Pohang, Kyungbuk, Republic of Korea
 
  Pohang Accelerator Laboratory started its XFEL program from 2011. The XFEL project in Pohang Accelerator Laboratory (PAL) requires low beam-emittance, ultra-short bunch length, high peak current, high stability of beam energy. Therefore, beam diagnostics for SASE XFEL should be, focused on attaining femto-second precision in the measurement of temporal beam parameters, and sub-micrometer precision in beam position measurement. Charge measurement and energy measurement and their feedback are important as well. In this work, technical concepts regarding the diagnostic monitors will be summarized and present status of them will be described.  
 
MOPB66
Optimization of the Interferometry Beam Size Monitor in PLS-II  
 
  • J.G. Hwang
    Kyungpook National University, Daegu, Republic of Korea
  • J.Y. Huang, C. Kim, G.H. Kim, H.-S. Lee, S. Shin
    PAL, Pohang, Kyungbuk, Republic of Korea
  • E.-S. Kim
    KNU, Deagu, Republic of Korea
  • H.K. Park
    CHEP, Daegu, Republic of Korea
 
  Pohang Light Source-II (PLS-II) is recently upgraded to 3 GeV and the circumference, beam current, emittance of PLS-II storage ring are 281.82 m, 100 mA and 5.7 nm-rad, respectively. The storage ring includes an interferometry beam size monitor system in 2B beam line. It consists of the quadrature slit, lens, 650 nm wave-length filter and CCD camera. We will present the measurement results and the issues to optimize the beam size monitor system in the beam line.  
 
TUPA34 Inverse Response Matrix Computation for the Storage Ring Slow Orbit Feedback Control: Synthesized Topological Inversion Computation 1
 
  • J.M. Lee, J.Y. Huang, C. Kim
    PAL, Pohang, Kyungbuk, Republic of Korea
 
  Using the derivative response matrix between BPM-data and MPS-setting, we described the inverse computation methodology for the storage ring orbit feedback control. Practically useful for SOFB with assistance of FOFB, the inverse of SVD manipulation is less efficient because a type of consecutive instability noise irreversibly accumulates in the beam trajectory deviation. In contrast, a novel numerical recipe based on topological math can lead to a self-consistent solution, dramatically suppressing ill-posed instability problems. This approach, known as a singularity regularization method, makes it feasible to compute a system-matched de-noising filter. The response matrix in H/V dimensions reflects a global beam dynamics along the storage ring lattices. Matrix refinement manipulatcan can be made to filter out the uncertainty of measurement errors escaping from beam dynamics constraints. Then we believe that algorithm filter can be effective as a software part of FOFB control. Our math STIC (Synthesized Topological Inversion Computation*) appears to be the most reliable inverse computation methodology. Our PLS-2 response matrix will be presented to explain our ORBIT-STIC test.
* Jay Min Lee et al, presented at the 15th International Conference on X-ray Absorption Fine Structure, Beijing, July 22-28, 2012.
 
 
TUPB59
Beam Diagnostics of Injector Test Facility for PAL XFEL  
 
  • S.J. Park, H. J. Choi, J.Y. Choi, J.H. Han, J.H. Hong, H.-S. Kang, C. Kim, I.S. Ko
    PAL, Pohang, Kyungbuk, Republic of Korea
  • M.S. Chae
    POSTECH, Pohang, Kyungbuk, Republic of Korea
  • A.Y. Murokh
    RadiaBeam, Santa Monica, USA
 
  Funding: Supported by the Ministry of Education, Science and Technology in Korea.
We are constructing an injector test facility (ITF) for the PAL XFEL. The target of the facility is to demonstrate an emittance of < 0.5 mm mrad (projected, normalized rms) at the beam charge of 200 pC with small energy spread and high stablities. By collaborating with the RADIABEAM Technologies*, we have developed beam diagnostics with enough precision and reliability to provide beam information including beam energy, energy spread, charge, profile, position, and bunch length. Resolutions of the beam-size and position measurements will be 17.5 um (rms, for OTR screens) and < 10 um (rms) respectively. A S-band transverse deflecting cavity will be used for measuring the bunch length with resolution down to 10 fs. In this article we report on current status of the PAL-XFEL injector test facility with emphases on its beam diagnostics.
* http://www.radiabeam.com/