Author: Chen, J.
Paper Title Page
TUPA01 Diagnostics Update of the Taiwan Photon Source 1
 
  • C.H. Kuo, J. Chen, Y.-S. Cheng, P.C. Chiu, K.T. Hsu, S.Y. Hsu, K.H. Hu, C.Y. Liao, C.Y. Wu
    NSRRC, Hsinchu, Taiwan
 
  Taiwan Photon Source (TPS) is a 3 GeV synchrotron light source which is being construction at campus of NSRRC. Various diagnostics are in implementation and will deploy in the future to satisfy stringent requirements of TPS for commissioning, top-up injection, and operation. These designs include beam intensity observation, trajectory and beam positions measurement, destructive profile measurement, synchrotron radiation monitors, beam loss monitors, orbit and bunch-by-bunch feedbacks, filling pattern and etc. are in final design phase. Progress of construction of the planned beam instrumentation system for the TPS will be summarized in this report.  
 
TUPA02 Modernized of the Booster Synchrotron Diagnostics in the Taiwan Light Source 1
 
  • C.H. Kuo, J. Chen, Y.-S. Cheng, P.C. Chiu, K.T. Hsu, S.Y. Hsu, K.H. Hu, C.Y. Liao, C.Y. Wu
    NSRRC, Hsinchu, Taiwan
 
  Taiwan Light Source is an 1.5 GeV synchrotron based light source which dedicated almost 20 year ago. During several major and minor upgrades, the TLS operate in top-up mode. To provide a better operation of the injector for the TLS, several minor upgrade in diagnostics are proceed recently. Efforts of these upgrades and modifications will summary in this report.  
 
TUPB64 Methods to Reduce the System Error for High Power MSSW Emittance Meter 1
 
  • S.X. Peng, J. Chen, Z.Y. Guo, P.N. Lu, H.T. Ren, Y. Xu, Z.X. Yuan, J. Zhao
    PKU/IHIP, Beijing, People's Republic of China
 
  Recently a new Multi-Slit Single-Wire (MSSW) type high power beam emittance meter named as HIBEMU-5 has developed in Peking University (PKU). Compared to previous MSSW devices, HIBEMU-5 greatly reduced the system error from 16.4% to 3.7% by specific designs to solve the incomplete short-slit sampling and fixed slit-wire distance. The problems of previous PKU devices are analyzed in part one. In part two, we describe the specific updating methods to solve its short-slit disadvantage by re-designing a longer-slit board with sufficient cooling, detail the mechanical scheme of changing the slit-wire distance for different beam divergence. The commissioning results given at part three prove that this new long slits design is successful to complete the beam sampling without being distorted by high power H+ beam. And the movable wire cup is able to locate the best measurement position for different beam focusing.  
 
MOPB53
Hartmann Screen and Wavefront Sensor System for Extracting Mirror at SSRF  
 
  • J. Chen, Y.B. Leng, K.R. Ye
    SINAP, Shanghai, People's Republic of China
 
  A Be mirror was used to extract visible synchrotron radiation light from bending magnet at SSRF. The surface of mirror was deformed because of X-ray heat. A set of Hartmann Screen Test was used to measure the surface of the mirror. Another equipment named The Shack-Hartmann wavefront sensor system was introduced to get more precision data. The result of two kind of test match each other well.  
 
MOPB70 The Synchrotron Radiation Diagnostic Line at SSRF 1
 
  • J. Chen, Z.C. Chen, G.Q. Huang, Y.B. Leng, K.R. Ye, W.M. Zhou
    SINAP, Shanghai, People's Republic of China
 
  The synchrotron radiation photon beam line has been operated since 2009 at Shanghai Synchrotron Radiation Facility. There are two diagnostic beam lines of the storage ring behind bending magnet, which is employed conventional X-ray and visible imaging techniques. A synchrotron radiation (SR) interferometer using visible light region in order to measure the small transverse electron beam size (about 22μm); low emittance and a low coupling. A small off-axis mirror is set for the convenience of the observation. Wave front testing is used for interferometer to calibrate the deformation effect of optical components. An X-ray pin-hole camera is also employed in the diagnostics beamline of the ring to characterize beam. Typically the point spread function of the X-ray pinhole camera is calculated via analytical or numerical method. Those two methods check each other. As a result, the measurement with SR system has quite enough resolution of itself even though the absolute beam size acquired. The existed system suffers with dynamic problem for beam physics studies. It has been measured 2.8nm.rad in small emittance mode at SSRF.  
 
TUPB81 Design of the Beam Profile Monitors for the SXFEL Facility 1
 
  • L.Y. Yu, J. Chen, Y.B. Leng, K.R. Ye, W.M. Zhou
    SINAP, Shanghai, People's Republic of China
 
  The Shanghai X-ray Free Electron Laser Facility will begin construction at next year. The linac electron beam energy is 0.84 GeV. Over 50 beam profile monitors with OTR and YaG screen will be installed along the linac and undulators. The profile monitor system design is a challenging task, since the system has to measure transverse electron beam sizes from millimeter down to 40μm scale with a 20μm resolution and 50μm repeat positioning accuracy. This paper describes the design of the mechanical detector , the integrated step-servo motor controlling system, the beam imaging system, as well as the software system.